Item
| Value
| Units
|
Supply voltage
| 12
| Vdc nom
|
12 V supply current
| 150
| mAdc nom
|
Control inputs' voltage
| 0 to 12
| Vdc nom
|
Digital outputs' sink current
| 1.5
| Adc cont max
|
5
| Adc peak max
|
Analog outputs' voltage
| 0 to 5
| Vdc
|
RS232 rate
| 19200
| baud
|
CAN rate
| 125, 250, 500 or 1000
| kHz
|
Reading rate
| 0.1 to 1.5
| readings / s
|
Number of cells monitored
| 1 to 255
| -
|
Operating temperature
| -40 to +85
| °C
|
Volume
| 0.8
| liters
|
Sensed battery current
| 5 to 600
| Adc
|
Cell voltage sensing range
| 2.09 to 4.54
| Vdc
|
Cell voltage sensing accuracy
| +/-20
| mVdc
|
Cell-board temperature sensing accuracy
| +/-4
| °C
|
Cell current drain, standby
| 2.0
| µA max
|
Cell current drain, operating
| 2
| mA nom
|
Cell current drain, balancing
| 200
| mA nom
|
Battery isolation
| 2.5
| kV
|
|
Detailed electrical specifications are in the Lithiumate™ Manual.
Symbol
| Item
| Conditions
| Min
| Nom
| Max
| Units
|
Vrange
| Cell voltage sensing range
| -
| 2.09
| -
| 4.54
| V
|
Vaccur
| Cell voltage sensing accuracy
| Within Vrange
| -
| ±10
| ±15
| mV
|
Isply
| Cell load current
| Stand-by
| -
| -
| 2.0
| µA
|
Active, 1-reading / sec
| -
| 1.5
| 2.0
| mA
|
Balancing
| -
| 200
| -
| mA
|
VISOL
| Isolation voltage
| End cell boards Between battery & low voltage
| -
| 2500
| -
| V
|
Mechanical specifications are in the Lithiumate™ Manual.
Radiated emissions, FCC part 15 class A