home support product_info specs

Lithiumate Pro Specifications

General specifications of the professional distributed Li-Ion BMS

Controllers

These are simplified specifications that may apply to a typical system.
Actual specifications depend on which components are used in a system.
Detailed specifications are in the manual

Item Value Units
Supply voltage 12 Vdc nom
12 V supply current 150 mAdc nom
Control inputs' voltage 0 to 12 Vdc nom
Digital outputs' sink current 1.5 Adc cont max
5 Adc peak max
Analog outputs' voltage 0 to 5 Vdc
RS232 rate 19200 baud
CAN rate 125, 250, 500 or 1000 kHz
Reading rate 0.1 to 1.5 readings / s
Number of cells monitored 1 to 255 -
Operating temperature -40 to +85 °C
Volume 0.8 liters
Sensed battery current 5 to 600 Adc
Cell voltage sensing range 2.09 to 4.54 Vdc
Cell voltage sensing accuracy +/-20 mVdc
Cell-board temperature sensing accuracy +/-4 °C
Cell current drain, standby 2.0 µA max
Cell current drain, operating 2 mA nom
Cell current drain, balancing 200 mA nom
Battery isolation 2.5 kV

Cell boards

Electrical specifications

Detailed electrical specifications are in the Lithiumate™ Manual.

Symbol Item Conditions Min Nom Max Units
Vrange Cell voltage sensing range - 2.09 - 4.54 V
Vaccur Cell voltage sensing accuracy Within Vrange - ±10 ±15 mV
Isply Cell load current Stand-by - - 2.0 µA
Active,
1-reading / sec
- 1.5 2.0 mA
Balancing - 200 - mA
VISOL Isolation voltage End cell boards
Between battery & low voltage
- 2500 - V

Mechanical specifications

Mechanical specifications are in the Lithiumate™ Manual.

Regulatory

Radiated emissions, FCC part 15 class A

 