Lithiumate Specifications General specifications of the professional distributed Li-Ion BMS | |
These are simplified specifications that may apply to a typical system.
Actual specifications depend on which components are used in a system.
Detailed specifications are in the manual
|
Item
| Value
| Units
|
Supply voltage
| 12
| Vdc nom
|
12 V supply current
| 150
| mAdc nom
|
Control inputs' voltage
| 0 to 12
| Vdc nom
|
Digital outputs' sink current
| 1.5
| Adc cont max
|
5 (HD: short circuit protected)
| Adc peak max
|
Digital outputs' voltage
| Pro: 18 V HD: self protected)
| Vdc max
|
Analog outputs' voltage
| 0 to 5
| Vdc
|
Communication links
| Pro: CAN & RS232 HD: CAN (isolated) & USB (isolated)
| -
|
RS232 / USB rate
| Rev < 2.00: 19200 Rev > 2.00: 57600
| baud
|
CAN rate
| 125, 250, 500 or 1000
| kHz
|
Reading rate
| 0.1 to 1.5
| readings / s
|
Number of cells monitored
| Pro: 2 to 256 HD: 2 to 200
| -
|
Operating temperature
| -40 to +85
| °C
|
Volume
| Master, Pro: 80 Master, HD: 35 Cell board: pouch: 0.1
| cl
|
Sensed battery current
| Pro: +/- 600 HD: +/-900
| Adc
|
|
Detailed electrical specifications are in the Lithiumate™ Manual.
Symbol
| Item
| Conditions
| Min
| Nom
| Max
| Units
|
Vrange
| Cell voltage sensing range
| -
| 2.09
| -
| 4.54
| V
|
Vaccur
| Cell voltage sensing accuracy
| Within Vrange
| -
| ±10
| ±15
| mV
|
Taccur
| Temperature sensing accuracy
| At cell board
| -
| -
| +/-4
| °C
|
Isply
| Cell load current
| Stand-by
| -
| -
| 2.0
| µA
|
Active, 1-reading / sec
| -
| 1.5
| 2.0
| mA
|
Balancing
| -
| 200
| -
| mA
|
VISOL
| Isolation voltage
| End cell boards Between battery & low voltage
| -
| 2500
| -
| V
|
Mechanical specifications are in the Lithiumate™ Manual.
Radiated emissions, FCC part 15 class A