Vinci BMS slaves For all Master/Slave BMS topologies | |
Slaves are required for any battery that uses a Master/Slave BMS topology.
|
Vinci BMS Slave
|
A VinciLink Wired Slave connects to a VinciLink Battery Master or to the previous Slave with a 2-wire link;
it connects to its cells through wire taps.
Each VinciLink is isolated from the cell side and is not referenced to any voltage;
the cell side is electrically referenced to the high voltage and is powered by the cells.
Part number
|
Description
|
3MK1200D
|
Slave, wired / VinciLink, Dissipative, 6~12 cells
|
3MK1600D
|
Slave, wired / VinciLink, Dissipative, 13~16 cells
|
3MK2400D
|
Slave, wired / VinciLink, Dissipative, 17~24 cells
|
|
VinciLink Slave
|
General specifications
Detailed specifications are in the Vinci BMS Manual.
A VinciBus Wired Slave connects to a Battery Master through the 5-wire VinciBus;
it connects to its cells through wire taps.
The cell side and the VinciBus side are isolated from each other;
the cell side is electrically referenced to the high voltage, while the VinciBus side is referenced to the vehicle's chassis.
On the cell side it is powered by the cells; on the VinciBus side it is powered by the Application Module.
Part number
|
Description
|
3MK1200D
|
Slave, wired / VinciBus, Dissipative, 6~12 cells
|
3MK1600D
|
Slave, wired / VinciBus, Dissipative, 13~16 cells
|
3MK2400D
|
Slave, wired / VinciBus, Dissipative, 17~24 cells
|
|
VinciBus Wired Slave
|
General specifications
Detailed specifications are in the Vinci BMS Manual.
A VinciBus Slave is connected to the Battery Master through a 5-wire VinciBus
and to the cell boards or cell modules through 2-wire cables.
It is powered by the Application Module.
It is isolated from the high voltage, and it is electrically referenced to the vehicle chassis.
Part number
|
Description
|
3MB0008W
|
Slave, VinciBus, wired, 8 banks
|
|
VinciBus Distributed Slave
|
General specifications
Detailed specifications are in the Vinci BMS Manual.
A VinciNet Wired Slave connects to the Battery Master wirelessly, and to its cells through wire taps.
It is powered by the cells.
It is isolated from the high voltage, and it is electrically referenced to the high voltage.
Part number
|
Description
|
3MN1200D
|
Slave, wired / VinciNet, Dissipative, 6~12 cells
|
3MN2400D
|
Slave, wired / VinciNet, Dissipative, 13~24 cells
|
|
VinciNet Wired Slave
|
General specifications
Detailed specifications are in the Vinci BMS Manual.
A VinciBus Fiber-optic Slave is connected to the Battery Master through a VinciBus (wires) and to the cell boards through optical fibers.
It is powered by the Application Module.
It is isolated from the high voltage, and it is electrically referenced to earth ground.
Part number
|
Description
|
3MB0004F
|
Slave, fiber-optic / VinciBus, 4 banks
|
|
VinciBus fiber-optic slave
|
General specifications
Detailed specifications are in the Vinci BMS Manual.
- As part of a complete BMS:
- For spare parts, please contact us